Jerome J. Lazar, RA, CCS, CSI, SCIP
Senior Member
Username: lazarcitec

Post Number: 1170
Registered: 05-2003
Posted on Monday, September 08, 2014 - 02:48 pm:   Edit PostDelete PostPrint Post

To reduce costs we are specifying rubber floor base in lieu of turning up resinous flooring at tenant bathroom walls for a commercial project in Trinidad. Eons ago, my father was a flooring installer and he used to apply a bead of sealant at the bottom of the wall base to ensure a watertight seal, does anyone specify this?
Steven Bruneel, AIA, CSI-CDT, LEED-AP, EDAC
Senior Member
Username: redseca2

Post Number: 454
Registered: 12-2006


Posted on Monday, September 08, 2014 - 03:49 pm:   Edit PostDelete PostPrint Post

I have seen that as a plan review comment for California hospitals reviewed by the state agency that issues hospital permits, OSHPD.
Wayne Yancey
Senior Member
Username: wayne_yancey

Post Number: 688
Registered: 01-2008


Posted on Monday, September 08, 2014 - 04:05 pm:   Edit PostDelete PostPrint Post

Yes we do.

1. Where coved base is installed against hard surface or resilient flooring, install a continuous bead of sealant under the toe of the base; ensure complete contact to exclude moisture between the floor and the base. Remove squeezeout with xylol, mineral spirits, or other solvent as recommended by the sealant manufacturer.