4specs.com    4specs.com Home Page

Rainscreen system as design build? Log Out | Topics | Search
Moderators | Register | Edit Profile

4specs Discussion Forum » Archive - Specifications Discussions #4 » Rainscreen system as design build? « Previous Next »

Author Message
David Axt, AIA, CCS, CSI
Senior Member
Username: david_axt

Post Number: 1089
Registered: 03-2002


Posted on Wednesday, April 14, 2010 - 04:06 pm:   Edit PostDelete PostPrint Post

Has anyone here specified an open joint rainscreen system as a contractor design build? When I say rainscreen system I mean to include: fasteners, insulation, z-girts, weather barrier, panels and mounting system.
(Unregistered Guest)
Unregistered guest
Posted on Thursday, April 15, 2010 - 06:08 pm:   Edit PostDelete PostPrint Post

Easy. Require that system pass AAMA 508 and you will be fine.
Anne Whitacre, FCSI CCS
Senior Member
Username: awhitacre

Post Number: 944
Registered: 07-2002


Posted on Monday, April 19, 2010 - 05:10 pm:   Edit PostDelete PostPrint Post

yes, but you have to give all the design criteria you care about, and all the testing criteria they are expected to meet. In addition, you need to draw the scope of work very carefully at the junction between the wall system and the supports, the sealants, drains, and other accessory items. but yes, I've done a lot of them.