Author |
Message |
David G. Axt, CCS, CSI ,SCIP Senior Member Username: david_axt
Post Number: 1541 Registered: 03-2002
| Posted on Wednesday, January 11, 2017 - 02:43 pm: | |
What MasterFormat number should I use for wood entrances and storefronts? Thanks. David G. Axt, CCS, CSI, SCIP Specifications Consultant Axt Consulting LLC |
Jeffrey Wilson CSI CCS SCIP Senior Member Username: wilsonconsulting
Post Number: 205 Registered: 03-2006
| Posted on Wednesday, January 11, 2017 - 03:13 pm: | |
I have used 08 4133 "Wood-Framed Storefront Systems". MasterFormat does include 08 4311 "Timber-Framed Storefronts." Jeffrey Wilson CCS CSI SCIP Wilson Consulting Inc Ardmore PA |
Guest (Unregistered Guest) Unregistered guest
| Posted on Wednesday, January 11, 2017 - 06:41 pm: | |
David - FYI; previously spec'd Duratherm Corporation as BOD for a Bahrain restaurant. |
J. Peter Jordan Senior Member Username: jpjordan
Post Number: 929 Registered: 05-2004
| Posted on Thursday, January 12, 2017 - 12:04 pm: | |
Depending on the specific application and whether or not you needed some sort of compliance with structural requirements, you could specify the frames and trim in Division 06 and the doors as glazed stile and rail doors in Division 08. J. Peter Jordan, FCSI, AIA, CCS, LEED AP, SCIP
|
|