Author |
Message |
Di Ann (Unregistered Guest) Unregistered guest
| Posted on Tuesday, September 13, 2016 - 01:24 pm: | |
We need a quick means of insulating a structural concrete deck, above an interior retail space to meet R30. This project is in California. Any recommendations would be appreciated. [Look to the spray insulations in http://www.4specs.com/s/07/07-2300.html Colin] |
ken hercenberg Senior Member Username: khercenberg
Post Number: 1014 Registered: 12-2006
| Posted on Tuesday, September 13, 2016 - 02:55 pm: | |
Are you able to use a closed cell SPF like BASF Walltite -http://www.spf.basf.com/ and then cover it with ICC's Ure-K - http://www.spray-on.com/products/urek/ for additional thermal insulation and fire barrier? Not sure if that creates a dew point and resultant rain forest inside or not. |
Di Ann (Unregistered Guest) Unregistered guest
| Posted on Tuesday, September 13, 2016 - 03:08 pm: | |
I will look into it. Thanks! |
Guest (Unregistered Guest) Unregistered guest
| Posted on Tuesday, September 13, 2016 - 06:38 pm: | |
Sprays could be messy; needing extensive clean-up and/or "masking" of non-insulated surfaces and below areas/floors. Have you considered semi-rigid insulation board with "stick-pins" to underside of concrete deck? |